GroLine Nutrient Dosing System (HI981413)

★★★★★ 5.0 144 reviews

US$161.00
Price when purchased online
Free shipping Free 30-day returns

Sold and shipped by www.ristic-prevodjenje.rs
We aim to show you accurate product information. Manufacturers, suppliers and others provide what you see here.
US$161.00
Price when purchased online
Free shipping Free 30-day returns

How do you want your item?
You get 30 days free! Choose a plan at checkout.
Shipping
Arrives Sep 25
Free
Pickup
Check nearby
Delivery
Not available

Sold and shipped by www.ristic-prevodjenje.rs
Free 30-day returns Details

Product details

Management number 250467319 Release Date 2026/09/17 List Price US$161.00 Model Number 250467319
Category

HI981413 Nutrient Dosing System

The HI981413 Nutrient Dosing System is engineered for maintaining the concentration of fertilizer in the nutrient solution used in hydroponics and irrigation water. The nutrient concentration in the water used for irrigation is critical for the successful propagation and growth of plants. Simply insert the probe and injection valve in-line with the recirculation pump and provide the chemical to be dosed.

  • Available in multiple configurations for easily integration into your setup.
  • Programmable alarm system and multicolored LCD display.
  • Perfect for small hydroponics systems.

       

      Peristaltic Dosing Pump

      The powerful built-in peristaltic pump uses a stepper motor which does not have any gears or brushes providing for a long life with little maintenance.

       

      Automatic Proportional Pump Control

      The peristaltic dosing pump can be controlled by simple on/off or more advanced proportional control which helps prevents overshooting of the set point.

       

      Adjustable Flow Rate

      The dosing pump flow rate is adjustable from 0.5 to 3.5L/h, allowing for better control in maintaining a desired set point.

       

      Acid Tank Level/Flow Switch Input

      A connection to an optional level controller or flow switch. This input can be used to disable the dosing pump when there is no chemical left in the reservoir tank or there is no flow due to the pump being turned off.

       

      Multicolored LCD Display

      A multi-colored LCD provides a quick way to see the status of the pool controller. The display will show green when operation normally and red while in an alarm state.

       

      Quick Connect Probe Input

      The Quick Connect DIN connector creates a waterproof seal with the meter making it ideal for reducing electrical noise issues with the connection caused by humid environments.

        

      GroLine EC/Temperature Probe

      The HI981413 uses the HI30033 amplified probe that incorporates both EC (TDS) and temperature sensors and connects to the controller with a single waterproof Quick Connect DIN connector.

      • PVDF body
      • 1/2” threaded fitting for insertion to an in-line “T” fitting or the flow cell

         

        Additional Info

        • Manual
         
         
         

        Specs

        Temperature Range: -5.0 to 105°C (23.0 to 221.0°F)
        Temperature Resolution: 0.1°C (0.1°F)
        Temperature Accuracy: (@25°C/77°F) ±0.5°C (±0.9°F)
        EC Range: 0.00 to 10.00 mS/cm
        EC Resolution: 0.01 mS/cm
        EC Accuracy (@25°C/77°F): ±2% F.S.
        TDS Range:
        • 0 to 4500 ppm (TDS conversion factor 0.45)
        • 0 to 9900 ppm (TDS conversion factor 0.99)
        TDS Resolution: 1 ppm
        TDS Accuracy (@25°C/77°F): ±2% F.S.
        TDS Conversion Factor: TDS conversion factor selectable from 0.45 to 0.99
        Temperature Compensation: automatic
        Temperature Coefficient: β can be set from 0%/°C to 2.4%/°C; default is 1.9%/°C
        Calibration:
        • EC: user calibration: automatic, one-point with standard solution (1.413 or 5.000 mS/cm)
        • Process calibration: single point, adjustable (±0.50 mS/cm around measured value)
        • TDS: through EC calibration
        Pump Control:
        • selectable flow rate (0.5 to 3.5 L / hour; 0.13 to 0.92 G/hour)
        • manual control for pump priming
        Alarms:
        • high and low with enable / disable option
        • triggered after 5 sec. if controller records a set of consecutive readings over / under threshold values level with enable / disable option
        • overtime protection (1 to 180 min. or off)
        • intuitive alarm system using red, light green, and green color-coded backlight
        External Event Input: input for level controller or flow switch to disable dosing pump in the event of no chemical when using a level controller or no flow when using a flow switch - galvanically isolated

        Alarm Relay Output: SPDT 2.5A / 230 VAC
        Casing: Wall mounted, built-in pump, IP65 rated
        Environment: 0-50°C (32-122°F), max. 95% RH non-condensing
        Power Supply: 100—240 VAC, 50/60 Hz
        Ordering Info:
        • HI981413-00 is supplied with HI30033 EC/TDS/temperature probe, conductivity calibration solution, 20 mL (3), power connection cable, instruction manual and quality certificates for instrument and probe.
        • HI981413-10 (with in-line mounting kit) is supplied with HI981413 controller, HI30033 EC/TDS/temperature probe, controller aspiration filter, controller injector, 1/2” thread, saddle for Ø 50 mm pipe (2), aspiration PVC tube (flexible) (5 m), dispensing PE injection tube (rigid) (5 m), valves (2), conductivity calibration solution, 20 mL (3), power connection cable, instruction manual and quality certificates for instrument and probe.
        • HI981413-20 (with flow-cell mounting kit) is supplied with HI981413 controller, HI30033 pH/temperature probe, flow cell for HI981413/BL101, mounting panel assembly for HI981413/BL101, controller aspiration filter, controller injector, 1/2” thread, saddle for Ø 50 mm pipe (3), aspiration PVC tube (flexible) (5 m), dispensing PE injection tube (rigid) (15 m), tubing adapter 1/2” - 6 mm with racord (2), valves (2), conductivity calibration solution, 20 mL (3), power connection cable, instruction manual and quality certificates for instrument and probe.
        Recommended Probe: HI30033 EC/TDS/Temperature probe with quick connect DIN connector - galvanically isolated
        Dimensions: 3.5 x 5.6 x 1.8”
        Weight: 32oz

            Correction of product information

            If you notice any omissions or errors in the product information on this page, please use the correction request form below.

            Correction Request Form

            Customer ratings & reviews

            5 out of 5
            ★★★★★
            144 ratings | 59 reviews
            How item rating is calculated
            View all reviews
            5 stars
            90% (130)
            4 stars
            0% (0)
            3 stars
            0% (0)
            2 stars
            0% (0)
            1 star
            10% (14)
            Sort by

            There are currently no written reviews for this product.